| Model | EC-4110-I | EC-4110-ICON | 
| Measuring modes | Conductivity/TDS/Salinity/Temp./Concentration(EC-4110-ICON
Only) | 
| Range | Conductivity | 0.0 μS/cm~2000 mS/cm
(depends on selected range); Auto or Fixed | 
| Salinity | 0.0 ppt~70.0 ppt | 
| TDS | 0 ppm ~ 19999 ppm ;
0.00~199.9 ppt | 
| Temp. | PT-1000/PT-100:
-30.0~200.0°C ; NTC-30K: -30.0~130.0°C | 
| Concentration |  | NaCl_28%:0~28% HCl_18%:0~18%, HCl_39%22~39% HNO3_30%:0~30%,HNO3_96%:35~96% NaOH_24%:0~24%, NaOH_50%:15~50% H2SO4_37%:0~37%,H2SO4_88%:28~88% H2SO4_99%:89~99% H2P04_35%:0~35% User-Defined Concentration Table (9temp.x9Concentration/Cond.matrix)   | 
| Resolutions | Conductivity | 0.1 μS/cm, 0.01mS/cm,
0.1mS/cm, 1mS/cm | 
| Temp. | 0.1°C | 
| Concentration |  | 0.01% | 
| Accuracy | Conductivity | ± 1% (± 1 digit) | 
| Temp. | ± 0.2°C (± 1 Digit),
Equipped with temperature error correction function | 
| Temperature
compensation | Automatic with NTC 30KΩ/
PT-1000 /PT-100 | 
| Manual
adjustment temp. compensation | 
| Calibration
mode | (1) Manual cell-constant
adjustment (2) Conductivity standard solution calibration | 
| (3)Zero-point
calibration | 
| Production adjustment | Factor: 0.7000~1.3000 | 
| Ambient temperature | 0~50°C | 
| Storage temperature | -20~70°C | 
| Cell constant | Freely adjustable
0.008~99.999cm-1 | 
| Temperature
coefficient | Linear temperature
compensation at 0.00%~40.00%, | 
| Non-linear
compensation and Off-compensation | 
| Compensation
Temperature | Freely adjustable &
setting for the specific temperature value: 0~200°C | 
| Display | Large LCM with
sensitization sensor for auto/manual illumination function and contract
function | 
| Text
mode: Numerical display | 
| Chart
mode: 3 mins real-time dynamic graph(Cond.& Concentration only) | 
| Trace
mode: Set up from 3 mins to four weeks duration of the measured value trend
graph(Cond.& Concentration only) | 
| Current output | Isolated DC 0/4~20mA
corresponding to measurement, max. load 500Ω | 
| Serial interface | RS-485(MODBUS RTU or ASCII) | 
| Modbus communications | Measuring value,
calibration data, product adjustment, logbook, parameter readout &
selection | 
| Logbook | 50 event records for
important events & diagnostic error records | 
| Setting | Contact | 240VAC, 0.5A max.
(recommend) | 
| Activate | Hi/Lo, Hi/Hi, Lo/Lo
selectable two limited programmable, ON/OFF | 
| Contact | Contact | 240VAC, 0.5A max.
(recommend) | 
| Activate | ON: 0~99min.59sec. /
OFF:0~999 hours59min. | 
| Power supply | 100~240VAC±10%, 7W Max.,
50/60 Hz | 
| Installation | Wall or pipe or panel
mounting | 
| Dimensions | 96 mm x 96 mm x 132 mm (H x
W x D) | 
| Cut out dimensions | 93 mm x 93 mm (H x W) | 
| Weight | 0.5 kg | 
| Protection | IP 65 (NEMA 4X) |