저울/기타계측기 >> 검사키트 - 납 >> 휴대형_ITS 모델 : Exact LEADQuick-W
 
재고여부 : 30일 이내
조달청 물품목록번호 : 41113319
조달청 물품식별번호 : 23142941
 
특징
1-500ug/L
(Lead in water)



 

Measurement Method

Photometric Light Source;

Light Emitting Diode(LED)

Wavelenght

476nm

Memory

20tests per menu; 120total

Programmed Tests

Lead in Water

Lead in Paint

Lead in Mercury

Lead in Cadmium

Photometric Precision

0.001

Cell Pathlength

20mm

Cell Chamber

Custom-molded, Proprietary,PET plastic fused

into chamber, non-removable

Sample required

4ml

Reagent System

Ultilizes patented eXact Strip Micro reagent delivery system

Operating Temperature Range

0~50

Power Supply

(4)AAA alkaline batteries

Battery Life

>2000 tests with alkaline batteries

Electromagnetic

Compliance

(EMC)

Emitted Interference-EN61326;

lmmunity to interference-EN61326

Waterproof

Rating

Exceeds IP67

Instrument

Weight

140g

Instrument

Dimensions

5(W)x3.5(D)x16.5(H)cm

Government

Compliance

European CE MARK

 

Menu

Test for

Range

Resolution

Typical(±%)

Accuracy

Limit

PA1

Diluted Homogenized Paint

Lead

.000 to 1.99

.001

.003 or 5%

 

PB2

Lead in Water

(auto-zero)

1-500ug/l

1ug/l

 3ug/L or 6%

3ug/L

HG3

Mercury in Water

(auto-zero)

10-600ug/l

1ug/l

 6ug/L or 6%

10ug/L

CD4

Cadmium in Water (auto-zero)

0.01-0.80mg/l

.01mg/L

.06mg/L or 6%

.02mg/L

PB2

Modified Test for

Lead in Soil

18-3000mg/kg

200-300,000

1mg/kg

200

± 25%

± 40%

18mg/kg

200mg/kg

PB2

Lead exracted from Ceramic

1-500ug/l

1ug/l

 3ug/L or

6%

3ug/l

 

 

About your Water Sample

If the water sample you are testing has a pH of 6.5 to 8.5, then the LEADQuick™

Reagent System will give valid results. If your water sample is below pH 6.5 or above

pH 8.5, or has a Total Alkalinity above 200 PPM; then the pH of the water needs to be

adjusted to between pH 7 and 8 before testing begins. Use 1.0N HCl or 1.0N NaOH to

adjust the pH of your water sample. Iron above 0.1 ppm can be present in well water

samples. It is recommended that the absence of iron be confirmed by the Iron Check

Test (part number 480025). If your results are different from what you expect, then

after the test is completed, check the pH of the reacted sample. The chemistry, to work

properly, should have a final pH of 9.0 to 10.0. If your pH is below 9.0, then add six

drops of PB-2 in step 5. If pH is above 10.0, then add four drops of PB-2 in step 5.

 

Kit Specifications:

The test detects from 0 to 500 μg/L or ppb levels of Lead as Pb2+. The most accurate test

range will be 3 to 200 μg/L. For this range, the Test resolution is 1 ppb, minimum detection

is 3 μg/L, and accuracy is +/-3 μg/L or +/-6% (whichever is higher), when used with an

eXact® LEADQuick™ Colorimeter. If lead level is above 500 μg/L (ppb), dilute sample with

lead-free water before retesting.

The MCL (Maximum Contaminant Levels allowed) for drinking water as set by the USEPA for

Pb2+ is 15 μg/L (WHO is 10 μg/L); Mercury (Hg+2) is 2 μg/L; and Cadmium (Cd+2) is 5 μg/L.

 

 

Exact LEADQuick-W 블로그 동영상 보러가기

구성내역
NO.1
eXact® LeadQuick Water Test Kit
  셋트일 경우엔 표준 부속품이 포함됨.
일부 사진만 표시될 수 있습니다.


  구성내역

eXact Reagent ACID-1 (486999)
eXact Reagent PB-2 (488375-B)
eXact Strip PB-3 (486997)
eXact Strip PB-4 (486995)
50ml Conical Tube
MSDS Sheet